RELIABLE PERFORMANCE

Xraybaggagescanner5030A2

X-ray machine KX5230

Line resolution: 38AWG
Spatial resolution: 1.0mm horizontal and vertical
Steel penetration: 10mm
Single examination dose: @ 1.6 μgy
Leaked radiation: @0.2 µgy/h
Film Safety: Ensure ISO1600 Film
tunnel size:
500 (West)×300 (H) mm
conveyor speed:
0.22 m/s
conveyor:
100kg
Dosage for a single check:
< 1.32 μ gy
wire resolution:
40AWG
steel penetration:
10mm
movie security:
x-ray generator
Location:
tube current:
0.4 ~ 0.7mA(adjustable)
anode voltage:
80KV(adjustable)
angle:
60°
generator cooling/duty cycle: sealed oil bath with forced air/100%
storage temperature: -20°c to 60°c
operating temperature:
0°c to 45°c
relative humidity:
20 to 95% non-condensing
system power supply:
220 VAC (±10%) 50±3Hz
power loss:
1.0 KW (maximum)
noise
<65DB
24-bit l-array detector
single energy
Image Performance System
Display:
High Resolution 19-inch Color LCD
Color Quality: 24-bit True Color Based on Materials
edge enhancement: object contour edges are more obvious
Super Image Enhancement: Image Details Brighter
high penetration display: increase the contrast of bright areas in the image to make the easily penetrating areas appear clearer.
Low penetration display: Increase the contrast of dark areas in the image to make the difficult-to-penetrate areas appear clearer.
magnifying glass:
partial amplification function
Brightening/Dimming: Increase/Decrease Image Brightness
image recursion:
displays the first 20 pictures and processes any of them.
image restoration:
The image is restored to its initial state.
Image storage:
Store any image in real time and process it in the running state.
Network interface:
can be connected to LAN and support multi-terminal checked baggage
safety ray:
rays are transmitted under automatic control to avoid errors.
One-click disable control:
Just rotate the key to turn off the machine; safe, easy and convenient
Hawkeye:
Self-diagnosis function:
fails, it will automatically send out information and maintain it in time.
tunnel size:
1200 (West)×1500 (H) mm
power requirements:
220V AC (±10%) 50±3Hz
power consumption:
1.0KW (maximum)
noise level:
<58dB
conveyor speed:
0.22 m/s
conveyor:
250kg
wire resolution:
38AWG
Spatial resolution:
1.0mm horizontal and vertical
steel penetration:
10mm
Dosage for a single check:
< 1.6 μ gy
leakage radiation:
<0.2 & micro;Gy/h
movie security:
guaranteed ISO1600 film
government
banking
education
office building
gym/stadium
factory